Pedestrian Alert PXALERT

Summary

The Proxicam External Pedestrian Alert (SKU: PXALERT-ENG / PXALERT-ESP) is a heavy-duty, outward-facing warning module designed to notify pedestrians when they breach an active machine's exclusion zone. By combining a high-intensity yellow LED strobe with a loud spoken voice alert, it guarantees immediate situational awareness and safety compliance in noisy or hazardous industrial environments.
 

System Features and Functions

Hardware and Environmental Durability

  • Heavy-Duty Construction: 
    Enclosed in a rugged die-cast aluminum body designed to withstand industrial wear and tear.
  • Ingress Protection: 
    Achieves an IP68 waterproof rating for complete protection against water and dust ingress.
  • Extreme Climate Operation: 
    Engineered to function reliably in extreme ambient temperatures ranging from -30°C to +80°C.
     

Audio-Visual Notifications

  • High-Intensity Strobe: 
    Emits a bright, flashing yellow LED strobe with a luminosity of 240Lm to capture pedestrian attention instantly.
  • Spoken Voice Alert: 
    Utilizes a built-in 5W speaker to deliver a commanding 103dB spoken notification ("Warning - Pedestrian").
  • Language Options: 
    English (PXALERT-ENG)
    Spanish (PXALERT-ESP) 
     

Installation and Usage

Mounting and Wiring

  1. Mount the PXALERT module securely to the exterior of the machine where it is clearly visible and audible to pedestrians approaching the exclusion zone. [TBD: Specific bracket mounting torque and placement dimension specifications].
  2. Route the connecting cable to the Proxicam Enhancement Box (PXE) or the 4-Pin accessory harness (4PT).
  3. Connect the module to the Alarm OUT and GND output trigger ports.
     

System Configuration

  1. Access the Proxicam Configuration App via a WiFi-enabled smartphone or tablet.
  2. Navigate to the Alerts & Triggers menu.
  3. Under the Pedestrian Alert section, toggle the required detection zones (Green, Yellow, Red) to ON to enable the output trigger for the PXALERT module.
  4. Set the Alert Language dropdown to either English or Spanish.
  5. Adjust the Trigger Duration (in milliseconds) to dictate how long the strobe and voice alert remain active upon a pedestrian detection event.
     

Technical Specifications

  • Operating Voltage: 8V - 36V DC
  • Current Draw: <400mA
  • Power Consumption: 12W MAX
  • Loudness (Avg) @50cm: 103dB
  • Speaker Power: 5W
  • LED Luminosity: 240Lm
  • Waterproof Rating: IP68
  • Dimensions: 100 x 100 x 45mm
  • Operating Temperature: -30°C to +80°C
     

Troubleshooting & FAQ
 

The PXALERT is not flashing or sounding when a person enters the exclusion zone. 
Ensure the output trigger is enabled for the specific zone (Green, Yellow, or Red) in the Alerts & Triggers menu of the Configuration App. Verify the wiring connection at the Alarm OUT port on the 4PT harness or PXE Enhancement Box.

How do I change the spoken warning language? 
The spoken alert is set in the device, it cannnot be changed by the user. 
 

Related Articles

  • Proxicam Enhancement Box (PXE) Technical Setup Guide
  • Proxicam Camera Configuration App User Manual
  • Proxicam Wiring Diagrams and Schematics
Was this article helpful?
0 out of 0 found this helpful