Summary
The Proxicam External Pedestrian Alert (SKU: PXALERT-ENG / PXALERT-ESP) is a heavy-duty, outward-facing warning module designed to notify pedestrians when they breach an active machine's exclusion zone. By combining a high-intensity yellow LED strobe with a loud spoken voice alert, it guarantees immediate situational awareness and safety compliance in noisy or hazardous industrial environments.
System Features and Functions
Hardware and Environmental Durability
- Heavy-Duty Construction:
Enclosed in a rugged die-cast aluminum body designed to withstand industrial wear and tear. - Ingress Protection:
Achieves an IP68 waterproof rating for complete protection against water and dust ingress. - Extreme Climate Operation:
Engineered to function reliably in extreme ambient temperatures ranging from -30°C to +80°C.
Audio-Visual Notifications
- High-Intensity Strobe:
Emits a bright, flashing yellow LED strobe with a luminosity of 240Lm to capture pedestrian attention instantly. - Spoken Voice Alert:
Utilizes a built-in 5W speaker to deliver a commanding 103dB spoken notification ("Warning - Pedestrian"). - Language Options:
English (PXALERT-ENG)
Spanish (PXALERT-ESP)
Installation and Usage
Mounting and Wiring
- Mount the PXALERT module securely to the exterior of the machine where it is clearly visible and audible to pedestrians approaching the exclusion zone. [TBD: Specific bracket mounting torque and placement dimension specifications].
- Route the connecting cable to the Proxicam Enhancement Box (PXE) or the 4-Pin accessory harness (4PT).
- Connect the module to the Alarm OUT and GND output trigger ports.
System Configuration
- Access the Proxicam Configuration App via a WiFi-enabled smartphone or tablet.
- Navigate to the Alerts & Triggers menu.
- Under the Pedestrian Alert section, toggle the required detection zones (Green, Yellow, Red) to ON to enable the output trigger for the PXALERT module.
- Set the Alert Language dropdown to either English or Spanish.
- Adjust the Trigger Duration (in milliseconds) to dictate how long the strobe and voice alert remain active upon a pedestrian detection event.
Technical Specifications
- Operating Voltage: 8V - 36V DC
- Current Draw: <400mA
- Power Consumption: 12W MAX
- Loudness (Avg) @50cm: 103dB
- Speaker Power: 5W
- LED Luminosity: 240Lm
- Waterproof Rating: IP68
- Dimensions: 100 x 100 x 45mm
- Operating Temperature: -30°C to +80°C
Troubleshooting & FAQ
The PXALERT is not flashing or sounding when a person enters the exclusion zone.
Ensure the output trigger is enabled for the specific zone (Green, Yellow, or Red) in the Alerts & Triggers menu of the Configuration App. Verify the wiring connection at the Alarm OUT port on the 4PT harness or PXE Enhancement Box.
How do I change the spoken warning language?
The spoken alert is set in the device, it cannnot be changed by the user.
Related Articles
- Proxicam Enhancement Box (PXE) Technical Setup Guide
- Proxicam Camera Configuration App User Manual